MOLD-06
HVAC & ATTIC
HVAC Air-Handler Closet & Return Plenum
Affected Envelope: 144 SF • 1,296 CF
1 Chambers • 2 Days
Engineering Specification
Fungal growth inside return-air plenum and air-handler closet requiring full system shutdown, critical register sealing, and dedicated HEPA negative air.
CONTAINMENT SF
144 SF
AIR VOLUME
1,296 CF
AIR TURNOVER
8 ACH (173 CFM)
6-MIL POLY
380 SF
Included Zones & Base Parameters
| Containment Zone | L × W | Ceiling | Floor SF | Volume CF | HEPA / Poly |
|---|---|---|---|---|---|
| Air-Handler & Plenum Closet | 12′×12′ | 9′ | 144 | 1,296 | 1 HEPA (173 CFM) • 380 SF 6-Mil Poly |
| Total (1 Zones) | — | — | 144 SF | 1,296 CF | 1 HEPA 500 CFM • 380 SF |
IICRC S520 Standards Applied
- ✓Cross-Contamination Lockout: Documents HVAC lockout/tagout and critical sealing of all supply/return boots.
- ✓8 ACH Mechanical Turnover: 1,296 CF × 8 ACH ÷ 60 = 173 CFM continuous HEPA filtration.
- ✓Copy-Ready F9 Note: Separates structural closet remediation from NADCA duct-cleaning subcontractor scope.
MOLDFLEX™ ENGINE
Generate S520 Containment Packet
Load this baseline scenario into MoldFlex™ or request early access to customize with your job logs.
Output Bundle:.pdf • .csv • S520 F9
Generation Speed:< 30 Seconds
Carrier Audit:100% Defensible