From .ESX Room Scopes to S520 Containment Packets in 30 Seconds
Justify every containment barrier, decon chamber, and HEPA Negative Air Machine with deterministic IICRC S520 math.
Step 1: Import .ESX, .SYM, or .CSV Scopes
Upload room scopes; MoldFlex™ parses room L×W×H and cubic footage while automatically excluding unaffected rooms from airflow math.
Step 2: Merge or Split Containment Zones
Combine open-concept rooms into a single containment or isolate individual rooms, and assign 3-stage decon vs. zipper access.
Step 3: Calculate 4–8 ACH & Scrubber Derate
Apply your target Air Changes per Hour (4–8 ACH) and 15% HEPA filter-loading derate to size exact Negative Air Machine counts.
Step 4: Export 5-File S520 Audit Bundle
Generate S520_Containment_Packet.pdf, 6-mil poly & PPE takeoffs, equipment logs, and copy-ready Xactimate F9 notes.
Why MoldFlex™ Scopes Never Get Kicked Back
Unaffected Room Exclusion
Unaffected rooms in your .esx file are explicitly flagged and excluded from containment cubic footage so adjusters never question inflated CF.
Realistic Filter-Loading Derate
Applies a configurable 15% HEPA filter-loading derate to rated scrubber CFM so your Negative Air Machine count is defensible.
6-Mil Poly & Decon Takeoffs
Wall/ceiling poly SF and 3-stage decon vs. zipper allowances are computed directly from clamped room geometry.
Zone,Room,Length,Width,Height,Affected,Decon Basement Zone,Utility Room,12,14,8,yes,3stage Basement Zone,Crawl Access,8,14,8,yes,3stage Main Level,Living Room,18,16,9,no,zipper
F9 NOTE: Basement Zone (2,240 CF) @ 6 ACH requires 224 CFM. With 15% filter derate on 500 CFM HEPA NAM (425 CFM net), 1 scrubber justified per S520. Living Room excluded. FILES: S520_Containment_Packet.pdf, Containment_&_PPE_Takeoff.csv