DRY-04
CLASS 4 / SPECIALTY
Vented Crawlspace Class 4 Bound Water
Affected Envelope: 680 SF • 2,720 CF
1 Chambers • 6 Days
Engineering Specification
Sub-grade Class 4 bound-water intrusion across floor joists, sill plates, and subfloor decking tracked against an 11% wood equilibrium dry standard.
AFFECTED SF
680 SF
CHAMBER VOL
2,720 CF
TARGET GPP
45 gr/lb
DRYING DAYS
6 Days
Included Zones & Base Parameters
| Chamber / Zone | L × W | Ceiling | Floor SF | Volume CF | Equipment / Target |
|---|---|---|---|---|---|
| Main Crawlspace Bay | 34′×20′ | 4′ | 680 | 2,720 | 6 Low-Profile (72°F / 38% RH) |
| Total (1 Chambers) | — | — | 680 SF | 2,720 CF | 6 Air • 1 Desiccant / LGR |
IICRC S500 Standards Applied
- ✓IICRC S500 Class 4 Specialty: Justifies extended 6-day bound-water drying curve for dense framing and subfloor.
- ✓Vapor Barrier & Poly Sealing: Documents temporary 6-mil ground poly and vent-block containment for closed-loop drying.
- ✓Dry Standard Proof: Logs unaffected control joist baseline (11% MC) alongside daily pin-meter readings.
DRYFLEX™ ENGINE
Run S500 Audit & F9 Notes
Load this baseline scenario into DryFlex™ or request early access to customize with your job logs.
Output Bundle:.pdf • .csv • F9 Note
Generation Speed:< 30 Seconds
Carrier Audit:100% Defensible